PTA Balloon for BTW lesions Intended use of Peripheral Balloon Catheter: Medical Peripheral Angiography Catheter used in the patient's coronary and peripheral vascular, and for a variety of diagnostic and therapeutic medical procedures.

Czatuj teraz
Wprowadzenie produktów

Product Overview 

PTA Balloon for BTW lesions come in various sizes, lengths and shapes,  depending on the anatomy they're intended to treat.match with three guidewire system,{{0}}.018 inch, 0.014 inch and 0.035  inch guide wire.  With two different design, coxial and doubel lumen to met different pass-ability and push-ability. 

Przeznaczenie cewnika balonowego peryferyjnego:
Medical Peripheral Angiography Catheter used in the patient's coronary and peripheral vascular, and for a variety of diagnostic and therapeutic medical procedures.

Product Features 


Balon medyczny PTA OEM do zmian BTW, cewnik dylatacyjny balonu PTA Cechy:

  • Advanced laser bonding technology 

  • Technika formowania laserowego końcówek

  • Doskonała wydajność przekraczania zwężenia

  • Soft tapered tip 

  • Kompensuje niewspółosiowość i ugięcia

  • Balon z 3 skrzydłami, żłobkowany

  • stożkowy drut rdzeniowy może zapewnić doskonałą wydajność dostarczania.

PTA-

Product Technical Specification

Compliance                                  

Balloon 

Rozmiar          

Długość balonu

Wał

długość

Projekt cewnika

Kompatybilność z prowadnicą Cal

SC  PTA Balloon

1,5 mm - 5. 0 mm

20-  210mmm

100/130/150 cm

współosiowy

0.014

SC  PTA Balloon

2. 0-9,0 mm

20-220mm

90/130/180 cm

współosiowy

0.018

SC  PTA Balloon

2. 0-9,0 mm

20-220mm

90/130/180 cm

podwójny lumen

0.018

SC  PTA Balloon

2. 0-10,0 mm

20-220mm

80/130 cm

współosiowy

0.035

SC  PTA Balloon

2. 0-10,0 mm

20-220mm

80/130 cm

podwójny lumen

0.035

NC  PTA Balloon

2. 0-5,0 mm

20-220mm

100/150 cm

współosiowy

0.014

NC  PTA Balloon

2. 0-7,0 mm

20-220mm

90/130/180 cm

współosiowy

0.018

NC  PTA Balloon

2. 0-7,0 mm

20-220mm

90/130/180 cm

podwójny lumen

0.018

NC  PTA Balloon

2. 0-10,0 mm

20-220mm

40/80/130 cm

współosiowy

0.035

NC  PTA Balloon

2. 0-10,0 mm

20-220mm

40/80/130 cm

podwójny lumen

0.035

More PTA Balloon for BTW lesions ordering information please contact your sales. 

 Barty Medical Profile 

Zhejiang Barty Medical Technology Co., Ltd. was established in August 2015 in Hangzhou Economic and Technological Development Zone. Engaged in two major lines of cardiovascular, peripheral vascular intervention and implantation. There are currently more than 100 employees in Barty Medical with an average age of 28 years. Company's core members are from internationally renowned foreign medical device companies with working experience more than 15 years.

 

FAQ


1. P: Czy możemy wykonać OEM dla balonu PTA dla zmian BTW?

Odp .: Tak, OEM, OBL jest dostępny.

2. P: Jak długo produkt jest ważny?

A: dwa lata

3. A co z wysyłką cewnika balonowego obwodowego?

Odp.: drogą morską, przez DHL, EMS lub inne!

4. P: Ile czasu zajmie zakup zamówienia?

Odp.: zgodnie z potrzebną ilością.

5. Q: what's the MOQ OF peripheral balloon catheter?

Odp .: zależy od sposobu, w jaki współpracujemy i różnych wymagań kraju.

Sposób kontaktu

Imię i nazwisko: Amanda Zhu

E-mail:qqzhu@batymedical.com

Mobile: plus 86 157 0559 1759 (whatsapp)


Popularne Tagi: Balon pta do zmian btw, Chiny, dostawcy, producenci, fabryki, dostosowane, OEM

Wyślij zapytanie

whatsapp

Telefon

Adres e-mail

Zapytanie

torba